Surgical Systems
Cleaning methods vary, see Resources for details
All
products listed in this catalog are certified except Instrument
Tables |
 |
|
OCULAR LANDERS WIDE FIELD VITRECTOMY LENS
155D lens produces wide angle inverted image. Allows
panoramic viewing of far peripheral retina. Clear image in fluid or gas
filled eye. Works well with hazy ocular media or through a small pupil.
Steam sterilizable, can be quickly prepared for a demanding surgical
schedule. Stable in tall sutured lens ring.
|
Product Code |
Image Mag. |
Lens Height |
Static FOV |
Dynamic FOV |
|
OLIV-WF |
0.38x |
11.8mm |
130° |
146° |
| |
 |
|
OCULAR LANDERS EQUATORIAL II VITRECTOMY LENS
91D wide angle lens. For procedures from the posterior pole
to the equator. Provides greater magnification and detail than Landers
Wide Field. Steam sterilizable for rapid re-use.
|
Product Code |
Image Mag. |
Lens Height |
Static FOV |
Dynamic FOV |
|
OLIV-EQ-2 |
0.65x |
14.4mm |
101° |
131° |
|
|
 |
OCULAR WOLDOFF HIGH MAGNIFICATION VITRECTOMY LENS
66D lens, ideal for wide angle viewing of the posterior
pole. Its wide field provides stereopsis well beyond the area seen by a
conventional flat lens. The high magnification and resolution create very
precise depth perception. It provides an excellent image for delicate work
around the macula such as macular hole surgery or peeling of epiretinal
membranes from the macula. Lens of choice for videotaping macular
procedures. Steam sterilizable for rapid re-use.
|
Product Code |
Image Mag. |
Lens Height |
Static FOV |
Dynamic FOV |
|
OWIV-HM |
0.9x |
13.6mm |
57° |
100° |
| |
 |
OCULAR LANDERS NON-AUTOCLAVABLE WIDE FIELD VITRECTOMY
LENS
Single-piece, 155D lens designed for clinical situations
where autoclaving is either not available or not desired. Excellent for
panoramic viewing of the far peripheral retina and laser photocoagulation
when managing a peripheral retinal tear or giant retinal tear. Its wide
field of view and low magnification make it particularly useful during
fluid-gas exchanges. Excellent lens for use with media opacities such as
cataracts and cloudy corneas, and works well through a small pupil. It is
the lens of choice for videotaping important procedures.
|
Product Code |
Image Mag. |
Lens Height |
Static FOV |
Dynamic FOV |
|
OLIV-WFNA |
0.38x |
11.8mm |
130° |
146° |
|
|
 |
OCULAR LANDERS NON-AUTOCLAVABLE EQUATORIAL VITRECTOMY LENS
Single-piece 91D lens designed for clinical situations where
autoclaving is either not available or not desired. It is excellent for
delicate membrane peeling around the optic nerve and off of the major
vascular arcades. It also provides an excellent image for delicate work
around the macula such as macular hole surgery or peeling of epiretinal
membranes from the macula.
|
Product Code |
Image Mag. |
Lens Height |
Static FOV |
Dynamic FOV |
|
OLIV-EQNA |
0.65x |
14.4mm |
101° |
131° |
|
|
 |
OCULAR WOLDOFF NON-AUTOCLAVABLE HIGH MAGNIFICATION VITRECTOMY
LENS
Single-piece, 66D lens designed for clinical situations
where autoclaving is either not available or not desired. It is ideal for
wide angle viewing of the posterior pole. Its wide field provides
stereopsis well beyond the area seen by a conventional flat lens. The high
magnification and resolution create very precise depth perception. It
provides an excellent image for delicate work around the macula such as
macular hole surgery or peeling of epiretinal membranes from the macula.
It also is the lens of choice for videotaping macular procedures.
|
Product Code |
Image Mag. |
Lens Height |
Static FOV |
Dynamic FOV |
|
OWIV-HMNA |
0.9x |
13.6mm |
57° |
100° |
|
|
|
for more products & information contact:
www.ocular-instruments.com |
|
::
back :: ::